2.4

Thermal Requirements

This section provides information on the thermal requirements of

the cPCI-6510 Series. Cooling of the board and its components is

provided by the thermal module (passive heatsink) and is depen-

dent on sufficient airflow from the chassis.
The amount of thermal energy that can by dissipated from the

board is dependent on the ambient air temperature and the airflow

rate of the chassis. To provide the user with guidelines for the

upper limits of operating conditions for the cPCI-6510, the follow-

ing sections give information on the maximum ambient air temper-

ature as a function of airflow rate for a given level of power

consumption.

Power Dissipation Graphs

The graphs shown below illustrate the level of CPU power dissipa-

tion that can be maintained dependent on ambient air temperature

and airflow rate. One graph is provided for each CPU supported

by the cPCI-6510. The curves on each graph indicate the upper

limits of operating conditions under which the CPU will not be

affected by its thermal management and protection systems at a

given percentage of the CPU’s thermal design power (TDP).
The CPU’s thermal management and protection systems begin to

take effect when the CPU temperature exceeds the maximum

junction temperature (T

j,Max

=105°C). When the ambient air tem-

perature and airflow rate are in the ranges below the TDP curves

on the graphs, the CPU temperature will remain below T

j,Max

and

the CPU will be able to operate at full performance (i.e. not limited

by thermal management).
The power dissipation graphs show two curves:

X

100% TDP

X

75% TDP

The detailed specifications for each processor can be found in

Section 3.1 "Processor" on page 17.