Warning – ADLINK cBP-3062 User Manual
Page 21
 
Power Supply Unit
• 11
3.1.3
Installation
After inserting cPS-150R to a standard 3U CompactPCI system or the 
standard 6U CompactPCI system, you can turn on the switch on the chassis. 
Of course, you may turn on the power switch on the chassis first, and insert 
cPS-150R, which delivers full safety redundant, hot-swappable function, and 
provides the plug-able feature. 
 
 
 
 
 
 
 
 
 
 
3.1.4
Specifications
u
AC Input
Item
Specification
Test Conditions
Operating Voltage
90 - 264 Vac, single phase
Input current
3.1 A max
Inrush current
<40A
@ 240 Vac
Frequency range
45-440 Hz
Power factor
0.99 typical
Efficiency
typical 73%
Protection
over current, over voltage, under 
voltage, and surge protection. 
u
DC Output
Item
Specification
Test Conditions
Output power
175W max.
For working area 
refer to figure 
3.1.4 
Output voltage
+5V, +3.3V, +12V,
−
12V
Output current
20A @+5V (2A min.) 
12A @+3.3V 
2A @+12V 
1A @
−
12V
Voltage error
<
±
3% @+5V
<
±
5% @+3.3V
<
±
5% @+12V
<
±
5% @
−
12V
WARNING
Be sure that the socket of the backplane on the 
chassis is ERNI part #914374; AMP#148370-1 or 
#97-7200 defined by PICMG before inserting 
cPS-150R to the chassis. If cPS-150R is forcibly 
inserted, it and the connector of the chassis will 
be damaged.