Power Supply Unit

• 13

meets EN55022 Class A

EMS:EN 50082-2

EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-8
ENV 50204

Impact & vibration
test

Frequency Range:
5Hz – 35Hz 5 min
35Hz – 55Hz 5 min
55Hz – 5Hz 5 min
Displacement: 0.38mm
Dweep time: 30 minutes for each axis
Duration: 2 cycles for three orthogonal
axis. Axis: X, Y, Z

Unpackaged,
Non-operating

Insulating strength

Primary - secondary: 4242Vrms
Primary - chassis ground: 3050Vrms
secondary - chassis ground: 500Vrms

Output insulation

Relatively to chassis ground, all
control signals and outputs are
floating SELV circuits.

Operation
temperature

0°C~70°C(the temperature on the
chassis)
Full power from 0°C to 40°C with 15
cfm forced air flow

Storing temperature

40°C to +85°C

Relative humidity

<95% @ 40°C, none condensation

Operation height

6,400m

Weight

about 0.85Kg

Figure 3.1.4 Working Area

0 10 20 30 40 50 60 70

Ambient °C

100

50

0

forced air 15 cfm

Advertising