Power Supply Unit
• 23
input for DC input power supplies. Front panel keying is provided to 
prevent damaging an AC power supply inserted into a backplane 
wired for DC and vice versa. 
 
CGND
Chassis GND signal shall be connected to safety ground with a low 
impedance connection. 
V1ADJ
V1 output voltage may be margined up to +10% if V1ADJ input is 
pulled to RTN or -10% if pulled to V1 using a programming resistor 
network. Typically usage is Rt=10K
. See Figure 2.1. An open
circuit on the backplane shall result in a nominal output voltage.
V2ADJ
V2 output voltage may be margined up to +10% if V2ADJ input is 
pulled to RTN or -10% if pulled to V2 using a programming resistor 
network. Typically usage is Rt=10K
. See Figure 2.1. An open
circuit on the backplane shall result in a nominal output voltage.
DEG#
Derating signal MAY be used as an output from the power supply to 
indicate that the supply is beginning to derate its power output. This 
signal is active low. It is a open collector, and should be pulled high 
by a 10K
resistor. Note that backplanes providing a power supply
connector shall connect DEG# to the backplane signal DEG# in the 
event that a power supply implementing this signal is installed. 
FAL#
Supply Fail signal MAY be used as an output from the power supply 
to indicate that it has failed. This signal is active low. It is a open 
collector, and should be pulled high by a 10K
resistor. Note that
backplanes providing a power supply connector shall connect FAL# 
to the backplane signal FAL# in the event that a power supply 
implementing this signal is installed. 
GA[2..0] The physical slot address (GA[2..0]) shall be encoded on the
backplane by grounding and leaving unconnected different 
combinations of pins at each connector. Physical slot addresses are 
defined by the physical slot number on the platform per Table 3-2-1. 
Due to the limited number of power supply geographic addresses 
available, physical slot numbers for power supplies are independent 
of physical slot numbers for CompactPCI boards. Power supply 
physical slot numbers shall start at 0 in the top-left corner of the card 
cage. Each signal shall be pulled up with a 10.KO ± 10% resistor on 
any power supply using the geographic addressing signals GA[2..0]. 
 
~
Caution:
1. Improperly connected 5S+,5S-, 3S+, and 3S- leads may damage the
power supply.
2. Because implementation and timing for V1 SHARE, V2 SHARE may
vary from manufacturer to manufacturer, interoperability between two or 
more power supplies from different manufacturers is not guaranteed.