Power Supply Unit

• 19

Temperature
Coefficient

0.05% / °C

Protection

1. All outputs protected against overload and short circuit. Straightline

current limiting, does not fold-back or latch-up during startup or load
transients. Automatic recovery.

2. Shutdown at internal heatsink temperature of 95°C. Automatic

recovery.

3. Shutdown at the output voltage exceeds the nominal voltage 20%.

Recycle power to reset.

Other

Item

cPS-175/AC

cPS-175/48

cPS-175/24

Output/Input
Connector

Positronic

PCI47M400A1

Indicator

Green LED indicating INPUT O.K.
Red LED indicating a power supply FAULT.

Switching
Frequency

100kHz

MTBF

100,000hr (by part counting MIL-HDBK0217E)

MTTR

5 Minutes (based on module replacement)

Safety

TUV/VDE EN60950

UL

CE

EMI: EN55022 Class A radiated and conducted
EMS:EN 50082-2 (IEC1000-4-2, IEC1000-4-4, IEC-4-5, IEC1000-4-11)

Shock &
Vibration

Frequency range: 5Hz~35Hz (5 min); 35~55Hz (5 min); 55~5Hz(5 min)
Displacement: 0.38 mm
Dweep time: 30 mins for each axis (X,Y,Z) duration 2 cycles for the
three orthogonal axis

Insulation

Primary –
Secondary: 3050Vrms
Primary – Chassis
Ground:3050Vrms
Secondary – Chassis
Ground:500Vrms

Primary –
Secondary:1150Vrms
Primary – Chassis
Ground:500Vrms
Secondary – Chassis
Ground:500Vrms

Primary –
Secondary:1150Vrms
Primary – Chassis
Ground:500Vrms
Secondary – Chassis
Ground:500Vrms

Output Insulation

Floating & SELV

Operating
Temperature

0°C~ 70°C(the temperature on the chassis)

Full power from 0°C to 40°C with 15 cfm forced air flow

Storage
Temperature

-10°C ~+85°C

Humidity

< 95% @ 40°C

Altitude

6,400m

Dimension

40.0 (W)

×

128.5(H)

×

172.8(D) mm

Weight

about 0.85kg

Note : minimal load 2 A @ +5V is required.