Power Supply Unit
• 25
Line regulation
The output line regulation for each output is less than +-1% while 
measuring at rated load and +-10% of 115VAC or 230VAC input 
voltage changing. 
u
Load regulation
The output voltage load regulation is less than the values in the 
following table by changing each output load +-40% from 60% rated 
load, and keep all other outputs at 60% rated load. 
Voltage
+5V
+3.3V
+12V
-5V
-12V
5VSB
Regulation +/-3%
+/-2%
+/-5%
+/-2%
+/-2%
+/-3%
u
Efficiency: The efficiency is higher than 65% while measuring at
nominal line and rated output.
u
Hold up time
The hold up time is longer than 20ms at 115 VAC input and rated load, 
which is measured from the end of the last charging pulse , to when 
the main output drops down to 95% output voltage. 
u
Over voltage protection
For some reason the power supply might fail to control itself , the 
build-in crowbar circuit will automatically shut down the outputs to 
avoid damaging the external circuits . The trip point of O.V.P. circuit is 
around 5.7V to 7.0V. 
u
Short circuit protection
The power supply will go into hiccup mode function against short 
circuit or over load conditions. If the faults condition removed, the 
power supply will restart automatically. 
u
Power good signal
The power is turned on, the power good signal will go high between 
100ms to 500ms after all output DC voltage are within regulation limits. 
u
Power fail signal
The power fail signal will go low at least 1ms before any of the output 
voltages fall below the regulation limits. 
u
Power ON signal
This TTL compatible signal (active low) is use to switch ON the main 
output . When Power on is disconnected from secondary common , all 
outputs except +5Vsb shall turn off . 
u
Environment Specifications