ADLINK cBP-3062 User Manual
Page 22
 
12
• Power Supply Unit
Ripple voltage
+5V............... 1.0 % p-p 
+3.3V............ 1.5 % p-p 
+12V............. 1.0 % p-p 
-12V ............. 1.0 % p-p 
The testing probe 
must be in parallel 
with a capacitor of 
22
µ
F and that of
0.1
µ
F.
Current sharing in 
parallel 
Any number of power supplies can be 
operated in parallel and will share 
current to within 10% 
only at +5V output
Load regulation
The output voltage of +5V changes 
within 
±
3% of allowed value.
Input voltage is 
from 90Vac to 
260Vac. Load is 
from 10% to 
100%. 
Line regulation
The output voltage of +5V changes 
within 
±
0.1% of allowed value.
Input voltage is 
from 90Vac to 
260Vac. Load is 
from 10% to 
100%. 
Hold up time
>6ms
Rising time
<200ms
Temperature 
coefficient 
0.05% /
°
C
Protection
All outputs protected against overload 
and short circuit. Straightline current 
limiting, does not fold-back or latch-up 
during startup or load transients. 
Automatic recovery. 
Shutdown at internal heatsink 
temperature of 95
°
C. Automatic
recovery. 
Shutdown at the output voltage 
exceeds the nominal voltage 20%. 
Recycle power to reset. 
u
Others
Item
Specification
Test Conditions
Input/output 
connector 
Male base is on the rear of power 
supply, and must meet IEC 603-2 
(DIN 41612) or IEC 1076. 
Indicator
Normal (green LED) 
Fail (red LED) 
Switching frequency 100KHz
MTBF
50,000 hours
MIL-HDBK-217E
MTTR
5 minutes
EMC
meets FCC and Class A of VDE
Safety specification UL 1950, CSA C22.2 NO.950,
EN60950/ TüV
CE
EMI: EN61000-3-2(1995),
EN61000-3-3 
harmonics