Serial ports, 12 serial ports – ADLINK CM3-GF User Manual

Page 45

Advertising
background image

TME-104P-CMx-GF-1V7

Rev 1.7

37 (81)

3.12 Serial Ports

Two serial ports are located on one IDC COM header. The ports work in either RS232 or RS485 mode,
selectable in BIOS. The 120 ohm termination resistor for RS485 mode is not on the module. Please use the
external termination resistor.

To enable the transmitters of COM1 and COM2 in RS485 mode, set the RTS# signal to ‘1’. Depending on your
operating system driver’s logic, this may mean setting a (non-inverted) RTS bit to ‘0’ in your application
software.

The serial ports are programmable in BIOS setup. When entering

ADVANCED SMSC SCH311X SIO

configuration of the serial ports is accessible.

The following settings are possible for COM1 and COM2 in Bios setup:

Serial Port:

enabled / disabled

Base address:

3F8h, 2F8h, 3E8h, 2E8h, 3A8h, 2A8h

IRQ:

3, 4, 7, 11, 15

MODE:

RS232, RS485

The default values are:

COM1

enabled, 3F8h, IRQ4, RS232

COM2

enabled, 2F8h, IRQ3, RS232

The maximum supported baud rates are:

1.5 Mbit/s in RS485 mode

430 Kbit/s in RS232 mode