Exception Codes

In case of an error, the SMC shows a blink code on the STATUS-LED. This error code is also reported by the
SMC Flags register. The Exception Code is not stored in the Flash Storage and is cleared when the power is
removed. Therefore, the “Clear Exception Code”-Command is not supported.

Exception

Code

Error Message

0

NOERROR

2

NO_SUSCLK

3

NO_SLP_S5

4

NO_SLP_S3

5

NO_PWRGD_ATX

6

NO_PWRGD_1V1A

7

NO_PWRGD_VCORE

8

NO_PWRGD_DDR3

9

NO_PWRGD_1V0S

10

NO_PWRGD_1V1S

11

NO_PWRGD_1V8S

13

+V3.3PCI

14

+V3.3IN

15

+V5S

16

+V5SBY

18

BIOS_FAIL

19

STACKING_ERROR

20

LOW_VIN