Rs485-termination, Cpu fan supply, Cpu fan connector (x18) – ADLINK CM3-GF User Manual

Page 47: 13 cpu fan supply

Advertising
background image

TME-104P-CMx-GF-1V7

Rev 1.7

39 (81)

RS485-Termination

Typically the RS485 cabling is done as a bus system with two or more devices on the bus. The cabling can be
done in 4-wire mode (RX+, RX-, TX+, TX- using four independent wires) or 2-wire mode (RX+, TX+ and TX-,
RX- using two combined wires). In RS485 Mode, the differential pairs should be terminated with 120

if the

device is located at the beginning or end of the bus.

The termination should be done externally at the connector by using an external 120

between the pairs (e.g.

between RX+ and RX-)

Additionally, positive/negative receive lines are pulled up/down on the module with 10k

to 5V/GND in order

to protect the transceivers of the CMx-GF from overvoltage.

It is recommended to protect the ports of the external device using the same method.

Caution: Using termination resistors in RS232 Mode will deactivate the serial ports.

3.13 CPU Fan Supply

The CMx-GF provides a connector to power a CPU fan, if the module requires active cooling.

CPU Fan Connector (X18)

Connector type:

Hirose DF13, 3-pin

Pin

Signal

1

Speed Signal from fan (yellow)

2

+5V (red)

3

GND (black)

Advertising
This manual is related to the following products: