ADLINK CoreModule 430 User Manual

Page 33

Advertising
background image

Chapter 3

Hardware

CoreModule 430

Reference Manual

27

Note: The shaded table cells denote power or ground. The * symbol indicates the signal is Active Low.

12

FP5

Panel Data 5 – Refer to pin 9, FP2, for more information.

13

FP6

Panel Data 6 – Refer to pin 9, FP2, for more information.

14

FP7

Panel Data 7 – Refer to pin 9, FP2, for more information.

15

NC

Not connected (FP8 = Panel Data 8)

16

NC

Not connected (FP9 = Panel Data 9)

17

FP10

Panel Data 10 – Refer to pin 9, FP2, for more information.

18

FP11

Panel Data 11 – Refer to pin 9, FP2, for more information.

19

FP12

Panel Data 12 – Refer to pin 9, FP2, for more information.

20

FP13

Panel Data 13 – Refer to pin 9, FP2, for more information.

21

FP14

Panel Data 14 – Refer to pin 9, FP2, for more information.

22

FP15

Panel Data 15 – Refer to pin 9, FP2, for more information.

23

NC

Not connected (FP16 = Panel Data 16)

24

NC

Not connected (FP17 = Panel Data 17)

25

FP18

Panel Data 18 – Refer to pin 9, FP2, for more information.

26

FP19

Panel Data 19 – Refer to pin 9, FP2, for more information.

27

FP20

Panel Data 20 – Refer to pin 9, FP2, for more information.

28

FP21

Panel Data 21 – Refer to pin 9, FP2, for more information.

29

FP22

Panel Data 22 – Refer to pin 9, FP2, for more information.

30

FP23

Panel Data 23 – Refer to pin 9, FP2, for more information.

31

TFTEnVcc TFT Power (Vcc) – This signal is the power to flat panel displays.

32

TFTEnVee

TFT Backlight Enable – This signal enables power to flat panel displays.

33

+PNLVdd

Voltage (+3.3 or +5 volts ±5%) depends on setting of JP6.

34

+12V Out

+12 volts ±5%

35

GND

Ground

36

GND

Ground

37

HSYNC

Horizontal Sync – This signal is used for the digital horizontal sync output to the
CRT. Also used (with VSYNC) to signal power management state information to
the CRT per the VESA

 DPMS standard.

38

VSYNC

Vertical Sync – This signal is used for the digital vertical sync output to the CRT.
Also used (with HSYNC) to signal power management state information to the
CRT per the VESA

 DPMS standard.

39

AGNDR

Analog Ground for Red

40

RED

Red – This pin provides the Red analog output to the CRT.

41

AGNDG

Analog Ground for Green

42

GREEN

Green – This pin provides the Green analog output to the CRT.

43

AGNDB

Analog Ground for Blue

44

BLUE

Blue – This pin provides the Blue analog output to the CRT.

Table 3-12. Video Interface Pin/Signal Descriptions (J11) (Continued)