Assembly, Operating temperature range – Bonaire Reverse Cycle User Manual

Page 13

Advertising
background image

Multi-Appliance Comfort Control

Page 13

Ducted Reverse Cycle

A

SSEMBLY

There is no assembly required of this Ducted Reverse Cycle Air Conditioner. Your Dealer or installer will
carry out all assembly and commissioning upon installation.

O

PERATING

T

EMPERATURE

R

ANGE

Although the controller will allow the operating set temperature to be adjusted between 5 to 36°C, it is
important that the controller settings be maintained within the following temperature ranges:

o

Heating

Only

Mode 16

to

27°C

o

Cooling Only Mode

18 to 32°C

o

Heating & Cooling Mode

18 to 27°C

The Bonaire air conditioner has been designed for the following temperatures. The operation of the Bonaire
air conditioner must be within this operational temperature ranges below.

Cooling

Temperature (°C)

Indoor

18 to 32

15 to 23

Outdoor

DB

5 to 43

WB

-

Heating

Temperature (°C)

Indoor 16

to

27 -

Outdoor

DB

-5 to 25

WB

-6 to 18


If the system is used when the temperatures are outside the operating ranges above, safety devices may
activate causing the system to stop.
If the system is used on heating below the minimum temperature ranges above, the outdoor heat
exchanger may freeze and cause the unit to malfunction and stop. If the system is to be installed in
locations where the ambient temperature falls below the minimum operating ranges stated above,
supplementary BOOST heating may be required (contact your dealer for advice on this option).