Multi-Appliance Comfort Control

Page 18

Ducted Reverse Cycle

H

EATING

M

ODE

-

M

ANUAL

1. Turn the comfort control ON, press and release the ON/OFF

button. When fitted to a Ducted Reverse Cycle system the control
will default to HEATCOOL.

NOTE: Your Comfort Controller is designed to automatically
detect the appliances you have installed, once coded. Controller
options not required for your appliances will usually not be visible
on your Comfort Control display. So don't worry if you don't see all
the menu items listed in this book.

2. Press the MANUAL/AUTO button until MANUAL is displayed.
3. Press the HEAT/COOL/FRESH AIR button until HEAT appears at

the top of the display.

4. Press & hold the ▼ or ▲ buttons to decrease or increase SET

TEMP or, press & release buttons to change the SET TEMP one
degree at a time. Set the temperature to your desired
temperature.
NOTE: The set temperature must be above the room temperature
before the system will begin heating operation
.

5. The Comfort Control measures the room temperature using a

thermostat inside its case. When the room temperature is cooler
than the SET TEMP the system will start.
NOTE: For safety operation there is up to a 3 minute delay before
the compressor will start. This safety time re-starts at every
compressor shutdown or when the main switch is first turned on.

6. The indoor fan will operate at the system selected speed; this can

not be changed by the user and has been selected by your
installer to provide you will the most optimum performance for
your system design.
NOTES: 1) The default fan speed for manual operation is High
speed. 2) Your Bonaire Ducted Reverse Cycle system
incorporates Bonaire’s unique SOFT HEAT function. This function
prevents the circulation of cold air while the system is in heating
mode. The indoor fan will automatically cycle on & off at startup to
allow the indoor heat exchange to heat up. Once the indoor heat
exchanger has reached the optimum temperature the indoor fan
will start and cycle off if the indoor coil temperature drops below
25°C (speak with your dealer if you wish to disable this option).

7. Press the ON/OFF button to switch the air conditioner OFF. OFF

will appear on the display.

8. The Comfort Control remembers your SET TEMP and operating

setting and uses them next time you turn it ON.

Advertising