The Ringer Detection Test Setup menu has the following configuration option.
TEST TYPE:
Fixed at Ringer Detection
14.2 Running a Ringer Detection Test
Use caution when connecting the test set, as telephone cables may have dangerous A.C. or D.C.
voltages on them.
Press the RUN / STOP button on the front of the CableSHARK to initiate the Ringer Detection test. Figure
14.2A shows an example of the results obtained from a Ringer Detection Test.
SAVE /
UPLOAD
MAIN
MENU
Ringer Detection (T-R)
Ringer Detection (T-G)
Ringer Detection (R-G)
E
F
CHG
:
:
:
1.0 REN, Cap = 0.47 uF
0.0 REN, Cap = 0.00 uF
0.0 REN, Cap = 0.00 uF
F
IGURE
14.2A
–
R
INGER
D
ETECTION
T
EST
C
OMPLETE
At the completion of a test, the function button command selection at the bottom of the Ringer Detection
Test Result screen consists of several options available to the operator. The following are brief descriptions