CableSHARK P3 User Guide
223
SEND TONE
600 OHMS
0
TRACING TONE
EDIT /
SELECT
MAIN
MENU
Test Type :
Term Impedance:
Level (dBm):
Frequency Mode:
E
F
CHG
SEND TONE
F
IGURE
15.1.4A
-
S
ETTING
U
P THE
T
RACING
T
ONE
The VF TEST menu has the following configuration option.
TEST TYPE:
Select SEND TONE
TERM IMP:
600 ohms (or 100, 150 ohms if your unit does not have 600 ohms installed).
Level (dBm):
Level can be set from –16 dBm to +18 dBm. Use the asterisk key ( * ) to toggle
between minus ( - ) and plus ( + ) symbols.
Frequency Mode:
Allows user to select from SPOT, VARIABLE, TX 3 TONE SLOPE and TRACING
TONE.
With TRACING TONE selected, press the RUN/STOP key to start the test. The following screen is
displayed.