Creating and Starting a Test Case
104
FTB-8100 Series Transport Blazer
Typical Test Cases
3. Interface selection.
3a. Press the desired interface: OC-3, OC-12, OC-48, OC-192, STM-1,
STM-4, STM-16, STM-64, OTU1, or OTU2. However, for the OTU1
and OTU2 interfaces, OC-N/STM-N must be part of the test path
(refer to Creating an OTN (OTU1 and OTU2) Test Case). Choices
depend on the rates available on the module.
3b. Press Next.
4. Select the test Path/Mapping.
4a. From the data path
selector, select
LOP VCG-1 or
HOP VCG-1.
4b. Press the desired
path/ mapping. See
Supported
Paths/Mappings on
page 59 for more
information.
For LOP VCG-1,
STS-1 is
automatically
selected for SONET and choices are AU-3 and AU-4 for SDH.
For HOP VCG-1, choices are STS-1-Xv and STS-3c-Xv for SONET,
VC-3-Xv and VC-4-Xv for SDH.