Error/alarm rx, Configuration, Alarm analysis – EXFO FTB-8100 Series Transport Blazer for FTB-500 User Manual
Page 413

Ethernet Tabs
SONET/SDH Application
399
Error/Alarm RX
Error/Alarm RX
The alarm/errors statistics are gathered on all received frames,
independently of the destination MAC address.
Press TEST, Ethernet / Gb Ehternet / 10G Ethernet, and Error/Alarm RX.
Configuration
Oversize Monitoring: Enables the monitoring of the Oversize error.
Alarm Analysis
³
Link Down: Indicates that the Ethernet connection is down. The
Ethernet connection is down when there is a local or a remote fault
condition.
³
Remote Fault: Indicates that a Remote Fault event is detected.
³
Local Fault: Indicates that impairments such as LOS, AIS, and OCI are
affecting the traffic. Available with Ethernet and 10G Ethernet only.
Note: Alarms/Errors are updated only during test execution.
Ethernet and
10G Ethernet
Gb Ethernet