Service Disruption Time (SDT) - Monitor
The channel grid provides the following monitoring information:
³
Current alarm/error for all channels.
³
Pass/Fail verdict and defect for each channel if global SDT threshold is
enabled.
³
Triggered on the selected defect for each channel selected if SDT
threshold is enabled.
³
The longest measured disruption time for each channel selected.
Different border and background colors are used to indicate the status of
each channel.
Color
Indicates
Monitoring Red border
Any alarm/error is currently active.
Red background
a
a.
Only available when the SDT threshold is enabled
At least one measured SDT value is
bigger than the configured threshold
(Fail).
Green background
a
All measured SDT values are smaller
or equal to the configured threshold
(Pass).
Channel
selection
Light blue background Channel selected for SDT
measurement.
Gray background
Channel not selected for SDT
measurement.
Dark blue background Channel selected to display its detail
analysis. Currently selected channel
has its detail information presented