System i/o connector pinout – Dukane iQ Series ULTRASONIC POWER SUPPLY AL ISO 9001:2008 User Manual

Page 24

Advertising
background image

Page  8 

iQ Series,

Ultrasonic Power Supply AL User’s Manual

Dukane Manual Part No. 403-583-00

Pin

Color

Description

1

BLK

Enable Out

2

WHT

Enable In

3

RED

System Overload Status Output

4

GRN

Ultrasound Active Status Output

5

ORN

Any Fault Status Output

6

BLU

System Power Status Output

7

WHT/BLK

Status Output Common (iQ Chassis Ground)

8

RED/BLK

System Ready Status Output

9

GRN/BLK

Power Signal Monitor Output (1mV = 1 Watt)

10

ORN/BLK

Power Signal Monitor Common (IQ Chassis Ground)

11

BLU/BLK

Fault Reset Input

12

BLK/WHT

Ultrasound Activate/Cycle Start Input

13

RED/WHT

Isolated Input Common (Sourcing or Sinking Inputs)

14

GRN/WHT

No Connection

15

BLU/WHT

No Connection

Table 3-II Generator Input/Output Signals

System I/O Connector Pinout

Table 3-II lists the signal names and descriptions, with
more detailed descriptions listed on the next page.

Pin 1

(Enable Out)

This is a current limited voltage source output intended
to connect to an E-Stop circuit. If an E-Stop circuit is
not used, Pin 1 must be jumpered to Pin 2 for ultrasound
operation to be enabled.

Pin 2

(Enable In)

The output from the E-Stop circuit is connected to this
pin when an E-Stop circuit is used. Otherwise, this pin
must be jumpered to Pin 1 for ultrasound operation to
be enabled.

See Figure A-1 in Appendix A for E-Stop

circuit wiring examples.
Pin 3

(System Overload Status Output)

Pin 3 is a non-isolated digital NPN status output that
activates when an output overload condition is tripped.
This output will be an open circuit if an output overload
condition is not tripped. This output will remain latched
ON until the U/S Activate input is switched OFF and
then ON again.

Pin 4

(Ultrasound Active Status Output)

Pin 4 is a non-isolated digital NPN status output that
activates when the system is delivering ultrasonic power
to the load attached to the ultrasound output connector.
This output will be an open circuit when the ultrasound
output is off.

Pin 5

(Any Fault Status Output)

Pin 5 is a non-isolated digital NPN status output that
activates whenever any fault condition is detected that
inhibits ultrasound output and normal system operation.
This output will be an open circuit when no system fault
conditions are active.

Pin 6

(System Power Status Output)

Pin 6 is a non-isolated digital NPN status output that
activates when no fault conditions are detected by any of
the power fault detection circuits included in the system.
This output will be an open circuit when any power
related fault condition is detected.