Stack disassembly – Dukane iQ Series ULTRASONIC POWER SUPPLY AL ISO 9001:2008 User Manual

Page 52

Advertising
background image

Page  4 

iQ Series,

Ultrasonic Hand Held Systems User’s Manual

Dukane Manual Part No. 403-583-00

HORN

HORN

PROBE

ASSEMBLY

PROBE

HOUSING

PROBE

HOUSING

A

SSEMBLY

D

ISASSEMBLY

Output End

Input End

Spanner

Wrench

Holes

Mounting Stud

(Insert Into Horn

First and Tighten

to Torque Specs)

Stack Disassembly

Stack disassembly is required when changing the booster or
horn, or for a thorough inspection of all stack components.
In mounted systems, always remove the stack from its
mounting to disassemble the stack components.

To establish a maintenance schedule, inspect the mating
surfaces after the first 200–400 hours of operation. If they
require cleaning, halve the time between inspections. If
the surfaces do not require reconditioning, then double the
time between inspections. Each system is different due
to the large number of operational parameters and stress
factors.

Figure 6–5 Probe Assembly and Disassembly

CAUTION

Never hold a probe by the

housing when tightening or

loosening an adjoining com-

ponent. The probe housing

has anti–rotation devices

to keep the transducer

aligned. These could shear

under excessive torque.

The assembly and disassembly procedures for a probe
are shown in Figure 6–5. It makes no difference whether
the horn is attached to the booster first, or the booster is
attached to the probe first.