Section 5 - Process Control Settings

Dukane Manual Part No. 403-583-00

Setup Maintenance

Introduction

The screens available in Setup Maintenance allow the
operator to Load, Store, or Delete generator weld setups.
As many as eight (8) setups can be loaded and stored for
your convenience.

Navigating

1. When the SETUP key is pressed for the first time, the

display looks like Figure 5-17. This screen indicates
that Setup #1 is Empty. Because there is not yet any
data available, this setup has nothing in it, and is
empty. You will see that Load is highlighted.

Press ENTER.

2.

Load

- (Load means to put data into the generator’s

memory, or to program a setup.)

A pop-up screen asks if defaults should be loaded for
Setup #1. See Figure 5-17A.

Select NO, and the display will change to an Operate
screen.

Select YES, and Automation Weld shows at the top
of the Operate screen that will display next. The setup
number appears in the lower left corner of the screen.
Refer to Figure 4-4.

3. After selecting YES, press SETUP, and the display

will look like Figure 5-19.

4.

Delete

-To delete the setup, select Delete as shown

in Figure 5-19, and press the ENTER key. A pop-up
screen appears to ask you to confirm your choice.

Select YES or NO, and press ENTER again.

Continued

Setup Maintenance

Load

Setup #

1

EMPTY

Delete

Figure 5-17 Setup Maintenance - 1

Setup Maintenance

Load

Setup #

1

T: 0.000 S A: 100%

Mode: Automation

E: 0 J H: 0.0 S

Delete

TBP: OFF

Figure 5-18 Setup Maintenance - 2

Setup Maintenance

Delete

Setup #

1

T: 0.000 S A: 100%

Mode: Automation

E: 0 J H: 0.0 S

Load

TBP: OFF

NO

Setup #1 Empty
Load Defaults?
YES

Figure 5-17A Pop-up Load Defaults?

Figure 5-19 Setup Maintenance - 3