Ramp Up Time
This parameter increases the amplitude linearly in
the programmed time period at the start of the weld
from zero to the programmed amplitude level. This
brings the probe up to operating amplitude smoothly
preventing shock stress.

Follow the on screen prompts to make setting

adjustments.

Lock and Hold
For an explanation of Frequency Lock and Hold,
please refer to Application Note 505 found on our
website at:
http://www.dukane.com/us/DL_ApplData.asp

Follow the on screen prompts to make setting

adjustments.

Trigger by Power
For an explanation of Trigger by Power and the
three settings that are connected with it, please refer
to Application Note 506 found on our website at:
http://www.dukane.com/us/DL_ApplData.asp

When Trigger by Power is selected, three additional
settings screens are presented:

Trigger Amplitude;

Trigger Power; and,

Trigger Timeout

See Figures 5-14, 5-15, and 5-16 for previews of
these screens

Figure 5-14 Trigger Amplitude

Figure 5-15 Trigger Watts

Figure 5-16 Trigger Timeout

Trigger By Power

Amplitude

40 %

_

Trigger By Power

Watts

80 W

_

Trigger By Power

Timeout

1.100 S