10 horizontal telescopic rear flue installation – Glow-worm 30ci Plus User Manual

Page 21

Advertising
background image

21

4000123944-2

10 Horizontal Telescopic Rear Flue Installation

10316

Diagram 10.8

RESTRICTOR

FLUE
HOOD

10316

Diagram 10.7

SEAL

Diagram 10.6

9741

POWER
SUPPLY
LEADS

EARTH
LEAD

FAN RETAINING
BOLTS

TWIST ANTI-CLOCKWISE
& LOCK AT 90

O

POSITION

NOTE: Please check orientation
when engaging bayonet spigot

FAN

Diagram 10.5

10.3 Fan Removal, refer to diagram 10.5

• Disconnect power supply leads and earth lead from fan.

• Unscrew and remove the two fan retaining bolts.

• Ease the fan down and forwards to remove.

10.4 Flue Connection, refer to diagram 10.6

Pull the flue assembly into the spigot bayonet connection and
twist anti-clockwise to lock.

10.5 Flue Hood Outlet Restrictor, refer to
diagram 10.8

Secure restrictor, supplied with flue pack, to the flue hood as
shown in diagram 10.8.

10.6 Fan Securing, refer to diagram 10.5

Ensure fan outlet seal is in position, see diagram 10.7, then fit
the fan into the flue duct and secure to the flue collector with
screws previously removed.

Replace chamber cover and secure with screws previously
removed.

Advertising