14 Commissioning

Bypass

The boiler has a built-in bypass, see diagram 15.1.

The boiler is supplied with the bypass open half a turn. It should
not be necessary to adjust the bypass, but if required ensure
that under no circumstances does the flow rate fall below the
figures specified, refer to Table 1. and diagram 1.1. (turn
clockwise to close the valve).

Boiler settings
(for use by installers and Service Providers only)

Press the button and keep pressed for 10 seconds.

This gives access to both the operating parameters and the
fault history.

When the menu is shown on display, select code 96

using button + or -.

Press the button , to show the first menu to be adjust

: Heating ouput

Note : The display will revert back to normal if no changes are
made after 1 minute or if the button is again pressed for
more than 10 seconds.

Parameter 1 : Setting the heating output
The maximum heating output of the boiler is adjustable between
the maximum and minimum values given in the Technical Data
section.

• When flashing, press on if you want to adjust this menu.

• Use the heating + and - button to set the desired heating
output in kW.
Note : Adjustment of the heating output does not affect the hot
water output.

For kW to Btu/hr conversion refer to table :

Parameter 02 : Setting the flue parameters
This adjustment is made to ensure the boiler operates at
maximum efficiency with longer flue lengths.

2.0

bar

45

°

C

10 s

96

1

2

3

1

2

3

1

20

2

10

Factory setting

Factory setting

Flue parameters following maxi. flue length :

Setting Horizontal

Horizontal Verticale

Horizontal

TOP Flue

REAR Flue TOP Flue

TWIN Flue

0

0,3 m

0,3 m

1 m

1,7 m

1

0,6 m

0,5 m

1,7 m

3,9 m

2

0,9 m

0,8 m

2,4 m

6,8 m

3

1,3 m

1 m

3,1 m

9,7 m

4

1,6 m

1,3 m

3,8 m

12,6 m

5

1,9 m

1,5 m

4,5 m

15,5 m

6

2,2 m

/

5,2 m

18,4 m

7

2,5 m

/

5,9 m

21,3 m

8

2,9 m

/

6,6 m

24,2 m

9

3,2 m

/

7,3 m

27,1 m

10

3,5 m

/

8 m

30 m

1

kW

Btu/hr

10

34,120

12

40,940

14

47,770

16

54,590

18

61,420

kW

Btu/hr

20

68,240

22

75,060

24

81,890

26

88,710

28

95,540

• Select a parameter
between

0 and 10 according to the following table.

15 Boiler Settings