INSTALLATION

5.2 Heating

circuit

5.2.1

Connection from the hydraulic module to
the heating circuit

i

Make the connection limiting the load losses to a
minimum (the circuit should be as short as possible,
avoid bends and narrow sections...).

5

6

7

1

3

4

2

Key
1 Heating

circuit

2

Return heating tubing leading to the hydraulic module (not
included)

3

Return heating circuit ¼ turn shut-off valve leading to the
hydraulic module (not included)

4

Return heating circuit fi lter leading to the hydraulic module
(not supplied)

5

Return heating connection (Ø ¾") leading to the hydraulic
module

6

Flow heating connection (Ø ¾") leading to the hydraulic
module

7

Flow heating tubing leading to the hydraulic module (not
included)

• Connect a pipe (2) to the return connection (5) leading to the

hydraulic module.

• Connect a pipe (7) to the fl ow connection (6) leading away

from the hydraulic module.

• Connect the pipes (2) and (7) to the heating circuit.