5.2 Heating
circuit
5.2.1
Connection from the hydraulic module to
the heating circuit
i
Make the connection limiting the load losses to a
minimum (the circuit should be as short as possible,
avoid bends and narrow sections...).
5
6
7
1
3
4
2
Key
1 Heating
circuit
2
Return heating tubing leading to the hydraulic module (not
included)
3
Return heating circuit ¼ turn shut-off valve leading to the
hydraulic module (not included)
4
Return heating circuit fi lter leading to the hydraulic module
(not supplied)
5
Return heating connection (Ø ¾") leading to the hydraulic
module
6
Flow heating connection (Ø ¾") leading to the hydraulic
module
7
Flow heating tubing leading to the hydraulic module (not
included)
• Connect a pipe (2) to the return connection (5) leading to the
hydraulic module.
• Connect a pipe (7) to the fl ow connection (6) leading away
from the hydraulic module.
• Connect the pipes (2) and (7) to the heating circuit.