Introduction – Glow-worm Clearly Heat Pumps - Standalone Module System User Manual

Page 8

Advertising
background image

0020096321_00 - 07/10 - Glow-worm

- 6 -

INTRODUCTION

2.4

Example of Installation – Diagram 4 (4.3) : Standalone + with 3 low heating temperature zones
(30-40°C) or 3 middle heating temperature zones (< 60°C)

i

Refer to the chapters “Hydraulic connection” and
“Electrical Connection” to connect the system.

b

This diagram shows the case of an installation with a
three zone low temperature heating fl oor
(= outlet temperature < 40°C).
Zones must be same temperatures.

230V

EBUS

D

E

C

B

A

230V

2

1

3

5

6

4

7

14

13

15

18

17

16

8

9

11

12

10

Key
1

Overheating safety (if underfl oor heating)

2

Heating circuit "zone 1" (UFH shown, but can be underfl oor or
radiators)

3

Climapro2 RF programmable wireless room thermostat "zone 1"

4

2 port valve "heating zone 1"

5

"Electrical" hydraulic module

6

2 port valve "heating zone 2"

7

Heating circuit "zone 2" (UFH shown, but can be underfl oor or
radiators)

8

Climapro2 RF programmable wireless room thermostat "zone 2"

9

Climapro2 RF programmable wireless room thermostat "zone 3"

10 Heating circuit "zone 3" (UFH shown, but can be underfl oor or

radiators)

11 2 port valve "heating zone 3"
12 Systempro control unit

13 Wireless outdoor sensor
14 "Electrical" hydraulic module electrical supply + protection

(This must have it's own single isolation)

15 Heat pump electrical supply + protection (This must have it's

own single isolation)

16 Heat

pump

17 Heat pump circuit fi lter (not supplied)
18 Glycol PRV discharge

A

Heating circuit return

B Heating

circuit

fl ow

C

Heat pump circuit safety valve discharge

D

Heat pump circuit fl ow

E

Heat pump circuit return