Installation, 2 internal connection, 3 system connection – Glow-worm Clearly Heat Pumps - Standalone Module System User Manual

Page 19

Advertising
background image

0020096321_00 - 07/10 - Glow-worm

- 17 -

INSTALLATION

6.4.2 Internal

connection

230V connection (High voltage)

1

3

L

N

230V~

1

3

L

N

REL1

1

3

L

N

REL2

1

3

L

N

REL3

1

2

L

N

REL4

1

2

L

N

REL5

1

2

L

N

IN1

3

2

1

Key
1

230 V connector (3-pin: earth / neutral / live)

2

Connectors (3 pins: earth / neutral / live): REL1, REL2 and
REL3

3

Connectors (2 pins: live / neutral): REL4, REL5 and IN1

24V connection (Low voltage)

1

2

2

1

OUT1

1

2

2

1

OUT2

1

2

2

1

OUT3

1

2

2

1

IN2

1

2

2

1

IN3

1

2

2

1

NTC1

1

2

2

1

NTC2

1

2

2

1

NTC3

1

2

2

1

NTC4

1

2

-

+

EBUS

1

2

-

+

EBUS

1

2

-

+

EBUS

2

1

Key
1

Connectors (2 pins) OUT1, OUT2, OUT3, IN2, IN3, NTC1, NTC2,
NTC3 and NTC4

2

EBUS connectors (2 pins)

6.4.3 System

connection

• Refer to the table below for the wiring of the systempro.

- Diagram 4 (4.1) : Standalone with 1 low heating

temperature zone (30-40°C) or 1 middle heating
temperature zone (< 60°C)

Key

Description

Cable min.

230V~

Control unit electrical supply

3 x 0.75 mm²

REL1

Domestic hot water cylinder 3-way valve

3 x 0.75 mm²

REL2

16A power relay for the domestic hot water
cylinder electric heater (not supplied)

3 x 0.75 mm²

NTC2

DHW cylinder thermistor (*)

2 x 0.75 mm²

EBUS

EBUS connection of the heat pump

2 x 0.75 mm²

EBUS

EBUS connection of the hydraulic module

2 x 0.75 mm²

- Diagram 4 (4.2) : Standalone with 2 low heating

temperature zones (30-40°C) or 2 middle heating
temperature zones (< 60°C)

Key

Description

Cable min.

230V~

Control unit electrical supply

3 x 0.75 mm²

REL1

Domestic hot water cylinder 3-way valve

3 x 0.75 mm²

REL2

16A power relay for the domestic hot water
cylinder electric heater (not supplied)

3 x 0.75 mm²

REL4

Heating circuit 2 port valve "area 2"

3 x 0.75 mm²

REL5

Heating circuit 2 port valve "area 1"

3 x 0.75 mm²

NTC2

DHW cylinder thermistor (*)

2 x 0.75 mm²

EBUS

EBUS connection of the heat pump

2 x 0.75 mm²

EBUS

EBUS connection of the hydraulic module

2 x 0.75 mm²

- Diagram 4 (4.3) : Standalone with 3 low heating

temperature zones (30-40°C) or 3 middle heating
temperature zones (< 60°C)

Key

Description

Cable min.

230V~

Control unit electrical supply

3 x 0.75 mm²

REL1

Domestic hot water cylinder 3-way valve

3 x 0.75 mm²

REL2

16A power relay for the domestic hot water
cylinder electric heater (not supplied)

3 x 0.75 mm²

REL3

Heating circuit 2 port valve "area 3"

3 x 0.75 mm²

REL4

Heating circuit 2 port valve "area 2"

3 x 0.75 mm²

REL5

Heating circuit 2 port valve "area 1"

3 x 0.75 mm²

NTC2

DHW cylinder thermistor (*)

2 x 0.75 mm²

EBUS

EBUS connection of the heat pump

2 x 0.75 mm²

EBUS

EBUS connection of the hydraulic module

2 x 0.75 mm²