Installation – Glow-worm Clearly Heat Pumps - Standalone Module System User Manual

Page 24

Advertising
background image

0020096321_00 - 07/10 - Glow-worm

- 22 -

INSTALLATION

10.4 Thermostat(s)

• Using the buttons

,

select Roomstat(s) on the screen.

• Press the button

to confi rm.

• Using the buttons

,

select the area controlled by the
room thermostat.

• Press the button

to confi rm.

On the room thermostat:

• Press the button

for 7

seconds.

• Enter the professional access code

(96).

• Via the installer menu > select > RF

> pairing.

• Press the room thermostat button

.

The control unit and the room
thermostat display “Connection fi nished
" on the respective screen.

If the message "Connection failed" is
displayed, press the button

and

repeat the operation.

• Repeat these operations for each

room thermostat (the zone number
is displayed on the thermostat at the
end of pairing).

• Press the button

twice.

10.5 Outdoor

sensor

• Using the buttons

, select

Outdoor sensor

on the screen.

• Press the button

to confi rm.

• Using the buttons

,

select Connection on the screen.

• Press the button

to confi rm.

• Press the button on the outdoor

sensor to connect.

ON

1

Key
1

Outdoor sensor button

i

Once the sensor is detected, the message
«Connection completed» is displayed.
If unsuccessful, the message "Connection failure" is
displayed.
Press the button

and repeat the operation.

• Press the button

.

i

The External T°C Correction allows you to correct
the temperature measured by the outdoor sensor
(+/- 5 ° C, at intervals of 1 ° C - factory setting: 0).

Advertising