Installation – Glow-worm Clearly Heat Pumps - Standalone Module System User Manual

Page 25

Advertising
background image

0020096321_00 - 07/10 - Glow-worm

- 23 -

INSTALLATION

• Using the buttons

,

select External T ºC correction on
the screen.

• Press the button

to confi rm.

This setting is automatically modifi ed in
the installer room thermostat menu.

• Increase or decrease with the

buttons

to display the

desired correction.

• Press the button

to confi rm.

• Press the button

twice.

10.6 Self

check

e

Do not modify the cables when connected to the
mains.

The automatic test allows you to check:

- EBUS inputs,

- NTC inputs,

- the RF connection with the room thermostat,

- the outdoor sensor radio connection.

The other connections are not tested and should be
visually inspected during installation or confi guration
modifi cations.

• Using the buttons

,

select Self check on the screen.

• Press the button

to confi rm.

• Check that all installation’s

components are switched on.

• Confi rm the start of the test with the

button

.

The automatic test will start.

The results appear in seconds,
indicating the status of each
component.

- If the connection is correct, the

message "OK" appears opposite the
component.

- If the connection is not correct, the

message "Not OK" appears opposite
the component.
In this case, check the connections.

10.7 Settings

This menu allows you to adjust different functions in accordance
with the connected appliances and to reset all the parameters.

• Using the buttons

,

select Settings on the screen.

• Press the buttony

to confi rm.

10.7.1 Heating

b

The maximum heating output temperature must be
adjusted in accordance with the characteristics of
your installation.

• Using the buttons

,

select Heating on the screen.

• Press the button

to confi rm.