INSTALLATION

- the batteries are not exhausted. If so, replace them with
fresh batteries.

i

If the signal quality does not improve, move the
thermostat to limit distances and obstacles.

• Repeat these operations for each room thermostat.

10.12.2 Reinitialisation of fault log

• Reset the fault reports of all system appliances (see chapter

"Activation of control unit > Component Info").

• Press the control unit button

for more than 3 seconds

to display the main screen.

10.12.3 Description of the main screen

This screen indicates:
- the overall system effi ciency,
- the current date,
- the time.

The date and time settings are confi gured via the room
thermostat.

• Consult the room thermostat instructions in order to adjust

settings.

10.12.4 System Performance Display

The performance indicator is based on the effectiveness of the
appliances during the past 24 hours.

Comment

Excellent

Good

OK

Standard

10.12.5 Status of appliances and system

The status of each of the installation’s components is checked
continuously. The result is displayed automatically every minute.

• Press the button

to

immediately obtain the status of the
installation.

After checking the installation, the
control unit displays the result for each
component and for the heating system
pressure.
The result can be:
- OK,
- NOT OK,
- _ _ (component not connected).

If the control unit displays "OK" for all appliances, no particular
action is required.

• If the control unit indicates <FAULT>, press the button

.

• If the control unit shows "_ _", check that the appliances are

switched on and connected to the control unit.

• Follow the indications on the control unit screen and consult

the "Troubleshooting" chapter for the corresponding failure
code.

11 Re-check and restart

• Once the system is installed, check the operation of each

appliance.

• Start the system to ensure that any adjustments operate

correctly and check that the appliances operate safely.

• Reset the fault reports for all appliances. To do this, see

chapter "Activation > Components Info”.

• Check the water-tightness of the appliances and eliminate

any leaks.

• Check the entire control and safety system, settings and

operation.

• Start the "Self check" procedure to test the system

connections (refer to the chapter “Commissioning the control
unit > Self check”).

12 User

information

At the end of the installation, the installer must:

- explain the operation of the appliances and its safety devices

to the user, if necessary provide a demonstration and answer
any questions;

- hand over to the user all the required documentation,

- fi ll in the documents where necessary;

- advise the user of the precautions necessary to prevent

damage to the system, appliances and the building;

- remind the user to service the appliances annually.

- The user shall not interfere with or adjust sealed

components.

- Any servicing must be carried out by a competent person

approved at the time by the Health and Safety Executive.