Key

1 2 port valve "heating zone 1"

2 Heating circuit zone 1

3 Climapro2 RF programmable wireless room thermostat "zone 1"

4 2 port valve "heating zone 2"

5 Heating circuit zone 2

6 Climapro2 RF programmable wireless room thermostat "zone 2"

7 2 port valve "heating zone 3"

8 Climapro2 RF programmable wireless room thermostat "zone 3"

9 Heating circuit zone 3

10 Systempro control unit

A Heating circuit return

B Heating

circuit

fl ow

Application conditions

- The Systempro control unit manages up to 3 heating zones.

- Each wireless room thermostat can control a heating zone.

- Zones must be same temperatures.

- The installation can be performed with a low-temperature

underfl oor heating (heating outlet temperature < 50°C) or low

temperature radiators (heating outlet temperature < 70°C).

e

Use 0.75 mm² section cables for the electrical

connections to the control unit.

Control unit settings

Description of main settings

Setting

Did you install a multizone kit ?

Yes

Max. heating fl ow temperature for the low

temperature zone

T < 30°C

Max. heating fl ow temperature for the high

temperature zone

T < 70°C

2 port valve electrical connections

- When the 2 port valve is connected to REL3:

•

Connect the neutral wire (blue) of the valve to the “N” of the

REL3 connector.

•

Connect the live wire (brown) of the valve to the “L” of the REL3

connector.

•

Connect the earth wire (yellow/green) of the valve to the earth

of the REL3 connector.

•

Electrically insulate the red and grey wires of the valve as they

are not used.

- When the 2 port valve is connected to REL4 or 5:

•

Connect the neutral wire (blue) of the valve to the “N” and

the live wire (brown) of the valve to the “L” of the REL4 or 5

connector.

•

Connect the earth wire (yellow/green) of the valve to the earth

of the REL3 connector.

•

Electrically insulate the red and grey wires of the valve as they

are not used.