2.1.2

Operating principle of the domestic hot water

system

The domestic hot water heating circuit consists of a heat pump,

a 3-way valve and a FLUROCYL hot water tank equipped with an

electric heater.

In order to always obtain the best comfort/economy trade-off ,

the heat pump and/or the FLUROCYL tank electric heater provide

the energy needed to maintain the stored water at the required

temperature.

The lower part of the tank is heated 3 times a day by the heat

pump. In order to provide maximum economy, the electric heater

heats the top part of the tank just to provide the comfort desired

by the user.

The lower the hot water temperature setting, the more the

heat pump will provide energy and, therefore, more economic

operation.

2.2

Summary of installation diagrams

Hybrid Back-up

Heat Pump

Diagram

Envirosorb 5

eBus

4

Envirosorb

2

7

Envirosorb

2

12

Envirosorb

2

15

controlled by on/off contact