Installation – Glow-worm Clearly Heat Pumps - Standalone System User Manual

Page 15

Advertising
background image

0020096321_01 - 02/11 - Glow-worm

- 13 -

4.2 Outdoor

sensor

1

Select Rmstat/sensor on

the screen.

2

Select Outdoor sensor on

the screen.

3

Select Connection on the

screen.

4

Press the button on the

outdoor sensor to connect.

b

The sensor is operational after 24h of exposure to

light and will therefore not function immediately after

being unpacked.

ON

1

Key

1 Outdoor sensor button

i

The External T°C Correction allows you to correct the

temperature measured by the outdoor sensor

(+/- 5 ° C, at intervals of 1 ° C - factory setting: 0).

5 Self

check

e

Do not modify the cables when connected to the mains.

The automatic test allows you to check EBUS inputs, NTC inputs,

the RF connection with the room thermostat, the outdoor sensor

radio connection.

i

The other connections are not tested and should be

visually inspected during installation or confi guration

modifi cations.

1

Select Self check on the

screen.

2

The automatic test will

start.

- If the connection is correct, the message "OK" appears

opposite the component.

- If the connection is not correct, the message "Not OK" appears

opposite the component.

In this case, check the connections (wired and wireless) .

INSTALLATION