Installation – Glow-worm Clearly Heat Pumps - Standalone System User Manual

Page 17

Advertising
background image

0020096321_01 - 02/11 - Glow-worm

- 15 -

6.2

Domestic hot water

i

The lower the temperature of the hot water, the more

economical the heat pump.

1

Select Hot water on the

screen.

2

Set max.Domestic Hot

Water temperature.

6.3 Cooling

Function not active for the UK.

6.4 HP

Management

This menu is used to set the outside temperature from which the

heat pump must turn off (value adjustable from -20°C to 20°C,

factory setting: 0°C).

To take full advantage of the heat pump, we recommend you to set:

- "-5°C" for 5 kW heat pump because it can not operate below -5°C.

- "-20°C" for the other heat pumps.

1

Select HP Management on

the screen.

2

Select Heat pump stop

temp. on the screen.

3

Set the outside

temperature from which the

heat pump must turn off .

Case of a heat pump controlled by On/Off contact

Refer to the heat pump installation notice to access the “after-

sales” parameters listed below.

Set the heat pump heating curves complying with the

correspondences with the Systempro control unit heating

curves (see table below).

b

Incorrectly setting these parameters may signifi cantly

impact the system effi ciency.

- Setting of the heat pump parameter 112:

Heating curve of the Systempro

control unit

Heating curve

of the heat pump

0.1 ▸ 02

7

0.3 ▸ 0.4

8

0.5 ▸ 0.7

9

0.8 ▸ 0.9

10

1.0 ▸ 1.2

11

1.3 ▸ Max.

12

- Example: Setting of the heat pump parameter 112:

Heating curve of the Systempro

control unit

Heating curve

of the heat pump

0.1 ▸ 0.2

7

0.3 ▸ 0.4

8

0.5 ▸ 0.7

9

0.8 ▸ 0.9

10

1.0 ▸ 1.2

11

1.3 ▸ Max.

12

In the case where the MODUZONE Z20 or Z30 option is installed:

if the curve setting is "1.2" on the control unit, the curve setting

will be "11" for heat pump parameter 112.

6.1.3 Pre

heating

The control unit manages the heating by anticipating the change

in temperature setting between two programmed time ranges.

This function allows it to reach the programmed temperature

more rapidly (factory setting: active). It acts at the fi rst morning

setting change for each zone.

1

Select Pre heating on the

screen.

2

Confi rm your choice.

INSTALLATION