0020096321_01 - 02/11 - Glow-worm

- 7 -

Key

1 Heat pump controlled by On/Off contact

2 Heat pump circuit fi lter (not supplied)

3 Hydraulic

module

4 Electrical power and protection of the heat pump

5 Electrical power and protection of the module

6 Heat pump control unit

7 Wireless outdoor sensor

8 Systempro control unit

9 Climapro2 RF programmable wireless room thermostat

10 Heating

circuit

11 Overheating safety (UFH shown, but can be underfl oor or radiators)

12 Glycol PRV discharge

A Heating circuit return

B Heating

circuit

fl ow

C Heat pump circuit safety valve discharge

D Heat pump circuit fl ow

E

Heat pump circuit return

Application conditions

- The Systempro control unit manages the operation of the

boiler, the heat pump and the module.

- The Systempro control unit manages up to 3 heating zones.

- The heat pump command unit is used as a setting or

diagnostic tool.

- Each wireless room thermostat can control a heating zone.

- The installation can be performed with a low-temperature

heated fl oor (heating outlet temperature < 50°C) or low

temperature radiators (heating outlet temperature < 70°C).

- The overheating safety device must be connected to the

hydraulic module pump power supply.

e

Use 0.75 mm² section cables for the electrical

connections to the control unit.

Control unit settings

Description of main settings

Setting

Diagram no.

7

Did you install a multizone kit ?

No

Heating curves

0.1 - 1.5

Max. heating fl ow temperature

30°C < T < 70°C

Heat pump external shutdown temperature

-20°C < T < 20°C

Heat pump control unit settings

Refer to the heat pump installation manual to access the

“After-sales” parameters listed below.

Menu Function name

Setting

112

Heating curves (*)

7 - 12

114

ECO heating mode (*)

1 - 20°C

(*) Refer to the correspondence table in the “Settings > Heating”

section.