Installation, 6 settings – Glow-worm Clearly Heat Pumps - Standalone System User Manual

Page 16

Advertising
background image

0020096321_01 - 02/11 - Glow-worm

- 14 -

1

Select Htg curve settings

on the screen.

2A

With Automatic htg curve

activated.

2B

With the Automatic htg

curve deactivated, you must

choose a heating curve.

2B.1

Select Htg curve setting

on the screen.

2B.2

Choose the heating

curve (see curve and

explanations after).

b

Ensure that the heating curve setting is compatible

with the installation.

Heating curve

A

B

1

2

3

Key

1 Older

properties

with radiators

2 Standard/modern

house

with radiators

3 Highly insulated modern house with low temperature radiators or

underfl oor heating

A Heating

fl ow temperature (°C)

B External

temperature

6 Settings

This menu allows you to adjust diff erent functions in accordance

with the connected appliances and to reset all the parameters.

6.1 Heating

b

The maximum heating output temperature must be

adjusted in accordance with the characteristics of

your installation.

1

Select Settings on the

screen.

2

Select Heating on the

screen.

6.1.1 Max.

heating

fl ow temperature

b

Ensure that the heating curve setting is compatible

with the installation.

3

Select max. heating fl ow T°

on the screen.

4

Adjust the installation's

max. heating fl ow

temperature.

6.1.2 Heating

curve

The following menu allows you to select the heating curve (value

adjustable between 0.2 and 4 - factory setting: 0.5), which allows

you to obtain the maximum heating demand for the usual minimum

outdoor temperature for the region in which the sensor is installed.

The automatic heating curve function continually and automatically

seeks the most suitable value to ensure your comfort and

the effi ciency of your heating system. The optimum value is

obtained approximately 24 hours after the system is started. It is

recommended to activate this function.

INSTALLATION

EN

Advertising