Installation, 5 check the gas inlet pressure and gas rate – Glow-worm Flexicom sx User Manual

Page 26

Advertising
background image

0020107231_04 - 12/14 - Glow-worm

INSTALLATION

- 26 -

temperature by using the MODE and + (plus) or - (minus)

SELECTOR buttons.

● The appliance will then continue to fire in central heating

mode until the user controls are satisfied.

NOTE: After ignition the boiler will ramp slowly to full rate rather

than going immediately to full rate. This is an adaptive feature to

cope with small system requirements.

After a period of 10 minutes, check that the supply inlet

pressure of the boiler is still 20mbar, disconnect the pressure

gauge.

NOTE: The burner pressure cannot be measured at the gas

valve as it is altered by the suction of the fan and modulated

according to demand.

11.5 Check the Gas Inlet Pressure and Gas

Rate

The supply from the governed meter must be of adequate size

to provide a steady inlet working pressure of 20mbar (8in wg) at

the boiler. On completion, test the gas installation for tightness

using the pressure drop method and suitable leak detection

fluid, purge as necessary.

NOTE: Due to the modulating operation of the boiler and the

need to check the gas inlet pressure and measure the gas rate

at maximum rate, it will be necessary to force it to maximum.

Press the “reset” button on the controls fascia, release

and immediately press and hold in the “+” button. After

approximately 5 seconds “Hi” will be displayed. Pressing

MODE

MODE

Diagram 11.3

14601

the mode button when “Hi” is selected will force the boiler

to maximum rate, the display will flash between “Hi” and the

“default display” this will indicate the boiler has been forced to

maximum.

Operational Gas Inlet Pressure

With ALL other gas appliances operating, check the operational

supply pressure at the gas service isolation valve test point, see

diagram 11.2.

The nominal supply pressure for Natural Gas (G20) is 20mbar.

Turn the taps and appliances off, then disconnect the pressure

gauge.

Additionally the safe nominal maximum heat input of the

appliance can be achieved at an inlet pressure down to 15mbar.
NOTE:

The

BURNER PRESSURE cannot be measured and is

not used to measure the gas rate.

Gas Rate

Make sure that ALL other gas burning appliances and pilot

lights are off.

Check the gas rate using the gas meter test dial and stop

watch, at least 10 minutes after the burner has lit, see table

below for approximate rates.

In communal installations where the gas rate cannot be

measured it is acceptable to measure the combustion rate as

described in the servicing section.

On completion, press the “mode” and “+” buttons

simultaneously, this will reset the boiler.

18sx : 2.0m3/h (71ft3/h)

30sx : 3.0m3/h (107ft3/h)