Maintenance, 7 condensate trap, 8 casing panel seal check – Glow-worm Flexicom sx User Manual

Page 32

Advertising
background image

0020107231_04 - 12/14 - Glow-worm

MAINTENANCE

- 32 -

Diagram 12.11

12815

13006

Diagram 12.12

14737

SECURING

SCREW

SERVICE

FILL LEVEL

CONDENSATE

TRAP

Diagram 12.10

13007

12.7 Condensate Trap

NOTE: If the functional checks did not indicate poor

combustion then it is not necessary to service this

component.

The condensate trap does not normally need removing during

servicing unless the service fill level is at full, see diagram

12.12.

To flush the condense drain carefully pour water into the heat

exchanger and check that water flows freely to drain.

12.8 Casing panel seal check

NOTE: If the functional checks did not indicate poor

combustion then it is not necessary to service this

component.

Check the condition of the seal and replace if worn or damaged.

To replace remove the old seal and thoroughly clean the casing

surfaces. Fit the new seals, these are supplied to the correct

lengths and are in four pieces, for use on the sides, top and

bottom.