Maintenance, 9 expansion vessel, 10 fan/gas valve assembly – Glow-worm Flexicom sx User Manual

Page 40: 11 silencer assembly (rear), 12 spark electrode, 13 burner

Advertising
background image

0020107231_04 - 12/14 - Glow-worm

MAINTENANCE

- 40 -

Diagram 14.2

15584

14.9 Expansion Vessel

For access, refer to section 14.1.

Drain the boiler heating circuit, refer to section 14.2.

Undo the coupling at the base of the vessel, see diagram 14.2.

Remove the locking screw and spacer from the retaining

bracket at the top of the expansion vessel. Whilst holding and

also pushing down slightly on the vessel, remove the expansion

vessel retaining bracket by unhooking and sliding forward.

The expansion vessel can now be removed by sliding it forward

clear of its support guides.

When re-fitting a new gasket will be required between the

expansion vessel and coupling.

Refill, vent and pressurise the boiler.

Check for leaks.

14.10 Fan/Gas valve assembly

For access, refer to section 14.1.

Undo the tubing nut to remove the gas valve from the gas pipe

and any electrical connections, see diagram 12.6.

Remove the securing nut holding the fan retaining bracket,

press down on burner to ease removal of securing nut. Slide out

the fan retaining bracket.

Lift front of bracket away from stud and pull forward to release

the fan, see diagram 12.9.

Lift fan/gas valve assembly up and forward away from locating

studs.

Remove fan gasket and replace if necessary.

To replace the fan and retaining bracket correctly, insert into

slots on fan clamping bracket, see diagram 12.9, and locate

onto lugs on the burner.

14.11 Silencer assembly (rear)

For access, refer to section 14.1.

Remove the fan/gas valve assembly, see relevant sections.

Pull Silencer rear away from fan/gas valve assembly.

The rear silencer is a push fit so no tools or fixings are required

for its removal or fitting, see diagram 14.3.

14.12 Spark Electrode

For access, refer to section 14.1.

Remove the spark plug lead and earth lead.

Remove the two securing nuts, see diagram 12.5.

Withdraw the spark electrode by slowly pulling up and leaning it

forward towards the centre of the heat exchanger to ensure that

the electrode does not foul on the hole in the burner casing.

Check spark gap.

14.13 Burner

For access, refer to section 14.1.

Remove igniter unit, flue hood, fan and gas valve assembly and

spark electrode lead, refer to relevant sections.

Remove the flanged nuts and studs that secure the burner, note

that two studs at the rear also hold the fan clamping bracket,

see diagram 12.9.

NOTE: The burner gasket should be inspected but will not need

replacing unless there are signs of wear or damage.

IMPORTANT: Do not allow fixings, nuts, screws, etc. to fall

into the open flue hood sump, use a temporary cover whilst

removing any parts.

Diagram 14.3

13007