^Yb,p,d,s - RS232 serial Port communication setting

Syntax

^Yb,p,d,s

Parameter

b = Baud Rate

48=4800bps

96=9600bps

19=19200bps

38=38400bps

57=57600bps

11=115200bps

p = Parity (N, O, E)

N=none parity

O=odd parity

E=even parity

d = Number of data bits 7

8

s = Number of stop bits

1

2

Description

Serial Port communication setting

^Z - Reset to factory default settings

Syntax

^Z

Parameter

^Z: default value comes from EEPROM default area.

Description

Reset to factory default. Same as ~~INTERNALCOMMAND+INIT