Cx,ys,±value,prompt - Serial number setting

Syntax

Cx,ys,±value,prompt

Parameter

x = 0 to 9(up to10group), maximum combination up to 10 groups.

y = select the decimal

y  0~9, set serial number as Decimal numbers, the value of "y" is included in "s"

(start value of serial variable) as first digit.

y  A, set serial number as Hexadecimal numbers, the value of "y" (e,g, A) is not

included in "s" (start value of serial variable).

y  C, set serial number as Base 36 numbers, the value of "y" (e,g, C) is not

included in "s" (start value of serial variable).

s = start value of serial variable (up to 29-digit). You can use the leading spaces to

replace the leading zeros.

±

value = ±value of serial variable (up to 28-digit)

Prompt = prompt of serial variable (up to 20 characters), only applied on models with

LCD or EZ-Viewer.

Description

Set the serial number

Example

^Q50,0,0

^W100

^H10

^P3

^L

Dy2-me-dd

Th:m:s

C0,000,+1,Prompt

C1, 1,+1,Prompt

C2,AEE,+1,Prompt1

C3,CZYY,+1,Prompt2

AC,80,10,1,1,0,0,decimal with leading zeros: ^C0

AC,80, 80,1,1,0,0,decimal with leading spaces:

^C1

AC,80,160,1,1,0,0,hexadecimal: ^C2

AC,80,240,1,1,0,0, 0~9 A~Z: ^C3

E

decimal with leading zeros: 000

decimal with leading spaces: 1

hexadecimal: EE

0~9 A~Z: ZYY

decimal with leading zeros: 001

decimal with leading spaces: 2

hexadecimal: EF

0~9 A~Z: ZYZ

decimal with leading zeros: 002

decimal with leading spaces: 3

hexadecimal: F0

0~9 A~Z: ZZ0