Wx,y,mode,type,ec,mask,mul,len,roatae<cr, Data – GoDEX EZPL User Manual

Page 60

Advertising
background image

55

Wx,y,mode,type,ec,mask,mul,len,roatae<CR>data - Arrange QR code and Micro QR Code

Syntax

Wx,y,mode,type,ec,mask,mul,len,roatae<CR>

data

Parameters

x = Hori. of left-bottom pos. of barcode (unit: dots)

y = Vert. of left-bottom pos. of barcode (unit: dots)

mode = input mode (1 ~ 5)

1  Numerical data mode

2  Alpha numerical data mode

3  8-bit data mode*

4  Kanji data mode

5  Mixing mode (not available in Micro QR Code)

type = barcode type (1 ~ 2)

1  Model1 (original)

2  Model2 (enhanced)

3  Micro QR code

ec = error correction level (L、M、Q、H)
L  Low

M  Medium

Q  Medium high

H  High (not available in Micro QR Code)

mask = masking factor (0 ~ 7 or 8 for auto). When printing with Micro QR code, it must

be set to "0".

mul = multiple (1 ~ 8)

len = number of encoded data bytes, including carriage returns ↵ and line feed.

roatae =rotation of barcode (0 ~ 3)

0) 0° 1) 90° 2) 180° 3) 270°

data = bar code data.

*Note: if input mode is set to 8-bit data mode, the first four digits of bar code data

must indicate the data length in bytes. For example, if first four digits are 0015, that

means the data length of following bar code content must be 15 bytes.

Description

Arrange QR-code by setting.

Example

Q50,0,0

^L

W10,10,2,1,L,8,10,36,0

0123456789ABCDEFGHIJKLMNOPQRSTUVW

XYZ

E

Data mode: 2

Model type: 1

Error level: L

Masking factor: 8

Multiple:10

Data length: 36

Advertising