General installation recommendations installation, Mounting guidelines and tips – Hatteland Display HT B22 (Fanless) User Manual

Page 17

Advertising
background image

17

IND100210-13

General Installation Recommendations

Installation

Mounting Guidelines and tips

Even though the HT B22 is fanless with no cooling apertures in the chassis, the unit will produce a certain amount of

heat through the aluminium chassis. The top of the chassis as been designed with heat dissipation groves which

allow heat to be properly expelled.

In order to ensure a stable operation and prevent over-heat of the unit, please respect the following illustrations and

guidelines given below based on various mounting positions by using the Mounting Bracket Kit (HT 00270 OPT-A1).

Keep in mind that heat always travels upwards and that heat in general has to be led away from chassis, even with

the use of external fan blowing directly at the chassis, if needed, making sure the air can circulate and slowly

decrease in temperature. It is impossible to predict every possible installation scenario in this document, so use tips

below during installation planning.

▼ Inside a cabinet, placed flat with groves facing up

allowing heat to escape upwards. It is expected that

the cabinet has adequate aperatures in top to allow

accumulated heat to escape. It should be noted that

the size of the cabinet will impact how efficient the

cooling can become.

▼ Wall mounting. Make sure groves are aligned vertically as

indicated, allowing heat to escape upwards along with the

groves. Connectors can face upwards or downwards

depending on installation needs.

▼ Possible scenario for inside a cabinet, placed

flat with groves facing downwards allowing heat to

not escape at all. Please install cooling fan to make

sure the air/heat can circulate and lead away from

the chassis. Although a fan might help, this type of

installation is not recommended as the entire

concept of heat dissipation is not respected.

▼ Possible scenario for Wall mounting. Heat does not

escape properly (gets stuck between horizontal groves).

Please install cooling fan to make sure the air is circulated

away from the chassis to allow adequate cooling, or choose

the option in the table above.