API / VCOM Commands

Appendix

IND100077-132

Available Messages to Send:

Please review the last page of this section for a code example.

“SWI” - Retrieve Internal Software Version Query:

This query is sent to the unit in order to get the version. Any future revisions, such as CMD additions or changes to

the software will increment the software version. The unit will reply to this command with an ACK attention code. The

DATA field will be a ASCII text string indicating the software version, e.g: “SW101010-0180”.

Command Software Version query:

0x07

0xFF

0x53

0x57

0x49

0x00

0x06

Acknowledge / Response (“SW101010-0180”):

0x06 0xFF 0x53

0x57

0x49 0x0D 0xFA 0x53

0x57

0x31

0x30

0x31

0x30

0x31

0x30 0x2D 0x30

0x31

0x38

0x30 0x3C

“QDU” - QM57 Chipset Half-Duplex Mode:

This query is sent to the local unit in order to force Half-Duplex Mode for the physical external RS-485/RS-422

DB9Male connector. Review “Pin Assignment” chapter in this manual for connector details.

Set Half Duplex Mode:

0x07

0xFF

0x51

0x44

0x55

0x01

0x0E

0x00

0xFF

Acknowledge / Response:

0x06

0xFF

0x51

0x44

0x55

0x01

0x0F

0x00

0xFF

“QDU” - QM57 Chipset Full-Duplex Mode:

This query is sent to the local unit in order to force Full-Duplex Mode for the physical external RS-485/RS-422

DB9Male connector. Review “Pin Assignment” chapter in this manual for connector details.

Set Full Duplex Mode:

0x07

0xFF

0x51

0x44

0x55

0x01

0x0E

0xFF

0x00

Acknowledge / Response:

0x06

0xFF

0x51

0x44

0x55

0x01

0x0F

0xFF

0x00