HITEC X1 AC Plus: Single Port AC/DC Chargers User Manual

Page 24

Advertising
background image

24

BEFORE YOU BEGIN CHARGING YOUR BATTERY, MAKE SURE YOU HAVE
READ AND UNDERSTAND ALL OF THE WARNINGS AND SEFETY INFOR-
MATION CONTAINED ON PAGES 4-7.

After selecting the correct battery type, if the screen

does not read “

CHARGE

”, use the ✚ or ▬ buttons to

change it to the “

CHARGE

“ mode.

Press the

► button and the amp rate value will begin

fl ashing. Use the ✚ or ▬ buttons to adjust the value to

the desired rate. The amp rate should be set to 1/10 of capacity. The example

shows the appropriate amp rate setting for a 7Ah battery. Follow the instruc-

tions provided with your battery when setting the amp rate.

Press the

► button again and the voltage rate value

will begin fl ashing. Use the ✚ or ▬ buttons to set the

voltage and number of cells.

Pb

Charge Modes

Pb

Charge Mode

Lithium

Pb (Lead-Acid)

This program is only suitable for charging Pb (lead-acid) batteries with nomi-

nal voltages of 2 to 20V. A Pb (lead-acid) battery is signifi cantly diff erent from

NiCd/NiMH batteries. Pb batteries can only deliver current lower in comparison

to their capacity. The same restriction applies to the charging process. Conse-

quently, the optimum charge current can only be 1/10 of the capacity. A Pb bat-

tery cannot be used for fast charging, so please follow the instructions provided

by the battery manufacturer.

The X1 off ers the following NiCD/NiMH charge modes: Charge and Discharge.

BEFORE SELECTING A CHARGE MODE, IT IS CRITICAL THAT YOU SELECT
THE CORRECT TYPE OF BATTERY TO BE CHARGED. FAILURE TO DO SO
CAN RESULT IN DAMAGE TO THE BATTERY.

Selecting the Battery Type

After you power on the X1, press the ■ button repeat-

edly until you reach the “

Pb BATT

“ progam. Now press

the

► button to enter the program.

PROGRAM SELECT

NiMH BATT

Warning

Pb CHARGE
0.1A 2.0V(1P)

Pb CHARGE
0.7A 2.0V(1P)

Pb CHARGE
0.7A 12.0V(6P)

Warning

Advertising