Lithium

Additional Features & Settings

The Temperature Cut-off is turned on or off with the use of the optional

temperature probe by contacting the surface of the battery. If it is on, set the

maximum temperature that the charger should allow the battery to reach dur-

ing charging. Once the battery reaches this temperature, the process will be

terminated to prevent damage to the battery.

See pg. 28 for instructions on accessing the “

Temp Cut-

off

“ screen.

Press the

► button once and “

Temp Cut-off

“ will begin fl ashing.

Use the ✚ or

▬ buttons to toggle between

Temp Cut-off

and

USB Enable.

While “

Temp Cut-off

“ is fl ashing, the

► button again and the temperature

value will begin fl ashing. Use the ✚ or ▬ buttons to change the temperature

value. This value can be set between 20ºC and 80ºC.
Press

► to set the Temperature Cut-off .

During the charge>discharge or discharge>charge cycle, batteries increase in

temperature. The Waste Time program allows the user to specify the time delay

between cycles, allowing time for the battery to cool.
See pg. 28 for instructions on accessing the “

Waste Time

“ screen.

Press the

► button once and the timer value will begin

fl ashing. Use the ✚ or ▬ buttons to adjust the timer

value. The timer can be set to 0 to 60 minutes.
Press

► to set the Waste Timer.

USB Temperatre Cut-off

Waste Time

USB/Temp Select
Temp Cut-off 80C

Waste Time
CHG>DCHG 1min