25

Pb

Charge Mode (cont.)

Pb

Disharge Mode

Pb (Lead-Acid)

Press and hold the

► button and charging will begin.

Once charging has commenced, the charger will display

the following real-time information: Battery type, charg-

ing current, battery voltage, charging time and charged capactiy.
When charging is complete the X1 will chime.

After selecting the correct battery type (see pg. 24), if

the screen does not read “

DISCHARGE

”, use the ✚ or ▬

buttons to change it to the “

DISCHARGE

“ mode.

Press the

► button and the amp rate value will begin

fl ashing. Use the ✚ or ▬ buttons to adjust the value to

the desired rate. The amp rate should be set to 1/10 of capacity. The example

shows the appropriate amp rate setting for a 7Ah battery. Follow the instruc-

tions provided with your battery when setting the amp rate.

Press the

► button again and the voltage rate value

will begin fl ashing. Use the ✚ or ▬ buttons to set the

voltage and number of cells.
Press and hold the

► button and discharging will begin.

Once discharging has commenced, the charger will dis-

play the following real-time information: Battery type,

discharging current, battery voltage, discharging time and discharged capactiy.
When discharging is complete the X1 will chime.

Pb DISCHARGE
0.1A 2.0V(1P)

Pb DISCHARGE
0.7A 2.0V(1P)

Pb DISCHARGE
0.7A 12.0V(6P)

Pb-6 0.4A 14.70V
CHG 003:10 00029

Pb-6 0.4A 14.70V
DSC 003:10 00029