Troubleshooting • 5 – Pitney Bowes DI950 FastPac Inserter User Manual

Page 103

Advertising
background image

SV61311 Rev. E

5-11

Troubleshooting • 5

Table 5-6 Insertion Area/Envelope Flapper Area Problems

Problem

Cause

Action

Stoppage in insertion area or

flapper area; failure to insert.

Outer envelope is skewed.

Check Side Guides; incorrect adjustment can cause

skewing.
Refer to Adjustng Tray Sde Gudes in Chapter 3 of

this guide for instructions.

Envelope openers improperly

adjusted.

Perform setup adjustment. Refer to Adjustng the

Envelope Openers in Chapter 3 of this guide for

instructions.

Insufficient edge clearance.

Check clearance: envelope width must be at least 13

mm greater than the sum of the width of the widest

insert plus the insert pack thickness.
NOTE: For the special case of a single piece into

a standard business envelope, 9 mm clearance is

sufficient.

Insertion pack or envelopes

not centered.

Ensure that Side Guides are set correctly. Too much

clearance between Side Guides and material can

cause material to become skewed in machine.
Refer to Adjustng Tray Sde Gudes in Chapter 3 of

this guide for instructions.

Contents of insertion

pack are catching on

side seam inside of

envelope.

Contents of insertion

pack are thick and

difficult to insert into

smaller envelopes.

Adjust the Aligner custom settings:
NOTE: If the contents of the insertion pack are

thick, and you are having trouble inserting the pack

into a small envelope, be sure to set the "Envelope

Width" and "Widest Enclosure Width" to the exact

dimensions of the insertion pack.
1. From the Home screen, select "Menu", then

"Jobs".

2. Select "Edit Current Job", "Edit Job Settings",

then "Advanced".

3. Select "Aligner", then "On with Custom Settings".

The Customer Aligner Settings screen displays.

4. Select "Envelope Width". Use the UP/DOWN

arrow keys to increase or decrease the

measurement, as necessary. Select "Accept"

when done.

5. Select "Widest Enclosure Width". Use the

UP/DOWN arrow keys to increase or decrease

the measurement, as necessary. Select "Accept"

when done.

6. Select "Accept" on the Custom Aligner Settings

screen once the necessary adjustments have

been made.

Advertising