8 • scanning, Setting up a bcr scan configuration (continued) – Pitney Bowes DI950 FastPac Inserter User Manual

Page 154

Advertising
background image

8-10

SV61311 Rev. E

8 • Scanning

6. The Create Scan Code screen ap-

pears. Enter the character, bit and

size information on the BCR Scan

Configuration Worksheet for a func-

tion.

Refer to BCR and OMR Mark Levels

in this chapter for a brief description

of the function of each mark.
a. Use the UP/DOWN and LEFT/

RIGHT arrow keys to highlight an

item within the grid.

b. Press "Increase" or "Decrease" to

edit the character (C), bit (B) and

size (S) information for a specific

function (F).

Setting Up

a BCR Scan

Configuration

(continued)

Scan Grid

F

C

B

S

MC

3

4

2

WAS

5

4

2

EOC

7

0

1

SF1

8

0

1

DVF

9

0

1

NOTES:

• On the BCR Scan Configuration Worksheet, look for the function abbrevi-

ation in the "Function" column. Enter the associated character information

in the "C" column, the bit information in the "B" column and, if necessary,

the size information in the "S" column.

• Bit 0 is the right-most bit (least significant) in each character:

- For Code 3 of 9 barcodes, bits are 5, 4, 3, 2, 1, and 0.

- For Interleaved 2 of 5 barcodes, bits are 2, 1, 0.

• Items with Character set to zero will no be included in the final code.

• For multi-bit fields, the entry in the "S" column depends on the code type.

For Bin, "S" is the number of bits. For CCD, "S" is the number of charac-

ters.

7. Select "Set Options". Use the table below to set the necessary options.

NOTE: The options that appear vary, depending upon the selected function.

Menu Option

Associated Options/Actions

Use When

Toggles:

Present, or

Absent.

When Present is selected, the function will be performed

when the bit is "1".
When Absent is selected, the function will be performed

when the bit is "0".

Count Direction

Allows you to specify the count direction.

Up (default),

Down, or

Random (MC only).

When Up is selected, the relevant code’s binary value will

increase as the system scans each page.
When Down is selected, the relevant code’s binary value will

decrease as the system scans each page.

Advertising