Setting up a bcr scan configuration, Setting up a bcr scan configuration -9, Ting up a bcr scan configuration in – Pitney Bowes DI950 FastPac Inserter User Manual
Page 153: Scanning • 8
SV61311 Rev. E
8-9
Scanning • 8
To setup a BCR Scan Configuration:
1. From the Home screen, select "Menu" then "Tools".
2. Select "Configure System" then "Scan Configuration Setup".
NOTE: If you are not logged in with supervisor or manager access rights, you
will be prompted to enter an access code.
3. Select the appropriate BCR Scan Type:
• Code 3 of 9
• Interleaved 2 of 5.
4. The Scan Configuration Setup screen for your selection displays. Select
"Create New Item".
5. Enter the Scan Configuration name using the alphanumeric matrix.
Press "Finished" when you are done.
NOTE: The Scan Configuration name cannot be longer than 9 characters.
Additionally, all names must be unique across all scan types. That is, a BCR
Scan Configuration name cannot be the same as an OMR Scan Configuration
name.
Setting Up
a BCR Scan
Configuration
Setting Up an
OMR Scan
Configuration
(continued)
Menu Option
Associated Options/Actions
LSB
Allows you to specify the least significant bit.
Toggles:
•
Last (default, farthest from top of page), or
•
First.
When Frst is selected for the Least Significant Bit option, the
least significant bit is closest to the top of the page.
When Last is selected, the least significant bit is farthest from
the top of the page.
10. Select "Finished' once you have set all of the necessary options for the
function.
11. Repeat steps 8 to 10 for each additional function on the OMR Scan Con-
figuration Worksheet.
12. Select "Finished" on the Create Scan Code screen once you have en-
tered and set up all of the functions.